product description: Heater type : D-8660
Installed heating power : 2 kW
Supply voltage : 230 Volt mono phase
Certification:
Area : Zone 1 & 2 hazardous areas
Temperature class : T3 (<200°C)
Certification heater : Ex ‘de’ IIC (incl. Gasgroups IIA and IIB)
Ingress protection : IP66
Standard : EN IEC 60079/1 - Ex II 2 G - ATEX 94/9/EC
Certifying Authority : ISSeP, Belgium
Process data :
Medium to be heated : water / Glycol mixture
Temperatuur in : TBA
Temperatuur uit : max. 60°C
Working pressure : 6 Barg
Flow : TBA
Mechanical design data :
Design code : Sinus Jevi standard
Design temperature : 110 / -15°C
Design pressure : 10 Barg
Description of the construction:
The heater consist of an electrical immersion heater bundle mounted in a vessel.
Immersion heater bundle :
Blindflange 3”150# RF in which 6 tubular heating elements are mounted.
Data on the elements:
Power on the elements : 333 Watt
Voltage : 230 Volt
Diameter : Ø 8.5 mm
Heated length : 810 mm,
Execution : U-pin
Watt density : 1,4 W/cm2
High-high protection (Limiter elements):
To protect the elements against overheating (High temp. trip) a capillary thermostat with manual reset, is clamped to an element skin. In case of over-heating the capillary thermostat signal will shut-off power to the heater bundle. The heater can only be re-started after a manual reset. Thermostat, 3-pole break contacts, 110ºC direct switching .
Temperature control of the coolant :
For temperature control of a capillary thermostat with, auto reset , is placed in a protective thermowell in the heater bundle near the outlet of the heater. Thermostat, range 30/85°C, 3-pole break contacts, direct switching, set at : 60°C.
Terminal enclosure
The electrical connections are placed in a “flameproof”terminal enclosure, protected against IP66. The elements are wired in one(1) stage of 2 kW to terminals.
All necessary cable glands are included.
Cable gland M 20 x 1,5 brass, type ICG
Tag plate stainless steel
Vessel:
Seamless tube, Ø 88.9 mm, one side closed with a 10% cap. Connections:
•Slip-on flange, 3”150# RF, for heater bundle 2 kW
• 1”NPT for coolant inlet
• 1”NPT for coolant outlet
• ¼”plug for drain
Coating:
4 Layer offshore coating + RAL 1028 - 70 μ
Features:
• Studs / nuts, gaskets
• Supports for horizontal mounting.